580 / 2019-03-20 21:14:51
Temperature and pressure calibration of Ultra High Pressure Assembly of 1000 T cubic press
high temperature and high pressure,cubic press,calibration,Thermocouple
Abstract Accepted
Guozhu Song / Department of Physics, Southern University of Science and Technology
The pressure limit of the conventional first-stage pressure chamber of the domestic cubic press is relatively low, about 6GPa, which restricts the development of domestic high-pressure science and related disciplines to a certain extent. Based on the assembly of the domestic cubic press, using the WC sheet as the pressurizing block, a new pressurized assembly was successfully developed, and the maximum pressure of the pressure chamber was up to 10 GPa. In addition to the use of pyrophyllite as a buffer outside the WC, it can protect the top hammer well and avoid damage, and has a certain heat preservation effect, so that it can run stably above 2000 °C.
Important Date
  • Conference Date

    May 29

    2019

    to

    Jun 02

    2019

  • Mar 20 2019

    Abstract Submission Deadline

  • Mar 20 2019

    Draft paper submission deadline

  • Apr 10 2019

    Abstract Notification of Acceptance

  • Jun 02 2019

    Registration deadline

Organized By
Institute of Applied Physics and Computational Mathematics
Laser Fusion Research Center, China Academy of Engineering Physics
Xi'an Jiaotong University
Contact Information