Improvement Measures of Active Intervention Arc Suppression Technology
ID:156 View Protection:ATTENDEE Updated Time:2020-11-11 12:09:52 Hits:288 Poster Presentation

Start Time:Pending(12)

Duration:Pending

Session:No Session »

No files

Abstract
In order to solve the problems of active intervention arc extinction device, such as PT inrush current, overvoltage after arc extinction and low start-up sensitivity for high impedance grounding faults, a new method which is the active intervention arc extinction device parallels with arc suppression coil is proposed in this paper. Its role for suppressing PT inrush current, post-overvoltage and significantly improving the start-up sensitivity is demonstrated. Effectiveness of the method is verified by experimental tests.
Keywords
distribution network,single-phase grounding,active intervention arc suppression,arc-suppression coil,start-up sensitivity