A Current Transformer Saturation Time Difference Method for Detecting Out Of Zone Fault Using Mathematical Morphology
ID:193 View Protection:PUBLIC Updated Time:2020-10-29 16:20:23 Hits:925 Poster Presentation

Start Time:2020-11-04 14:45(Asia/Shanghai)

Duration:5min

Session:G Poster session » G4Poster Session 4 and Poster Session 9

Abstract
For the smooth operation of the power system timely detection of fault and separation of faulty part is of utmost importance, so that the fault current do not travel to the other areas of the system causing severe outage or damage to the system relays must operate on their designed settings. Timely recognition of fault and the exact place where fault has occurred is very important and in order to avoid problems caused by difference in differential currents due to saturation of Current Transformer (CT), which causes distorted secondary current, resulting in mal Operation of relays, which can lead to severe problems in the system or possible damage to some of the power equipment. So it is necessary to detect CT Saturation and timely compensate its effects. This paper proposes an algorithm based on mathematical morphology to detect CT saturation caused by the fault in the system, and by using a time difference comparison it can detect when the fault is inside the zone of protection and the when the fault is outside the zone. This method is effective in determining CT saturation and in selecting the area of fault based on the time difference. The simulation experiment was done using PSCAD/EMTDC and MATLAB.
For the smooth operation of the power system timely detection of fault and separation of faulty part is of utmost importance, so that the fault current do not travel to the other areas of the system causing severe outage or damage to the system relays must operate on their designed settings. Timely recognition of fault and the exact place where fault has occurred is very important and in order to avoid problems caused by difference in differential currents due to saturation of Current Transformer (CT), which causes distorted secondary current, resulting in mal Operation of relays, which can lead to severe problems in the system or possible damage to some of the power equipment. So it is necessary to detect CT Saturation and timely compensate its effects. This paper proposes an algorithm based on mathematical morphology to detect CT saturation caused by the fault in the system, and by using a time difference comparison it can detect when the fault is inside the zone of protection and the when the fault is outside the zone. This method is effective in determining CT saturation and in selecting the area of fault based on the time difference. The simulation experiment was done using PSCAD/EMTDC and MATLAB.
 
Keywords
CT saturation, Mathematical morphology, Morphological gradient
Speaker
Ather Khan
Research And Develop Sieyuan High Voltage Electric Company, Shanghai

Studied Electrical Engineering from Mehran University of Engineering and Technology, Jamshoro Pakistan in 2010, work as lecturer in polytechnical institute hyderabad Pakistan. till April 2014. In Sep 2014 moved to China and finished M.S in Electrical Power System and Its AUtomation in 2018. Since 2018, October, working in Sieyuan High Voltage Electric Company, Shanghai as research and development engineer for Gas Insulated Substations.

Submission Author
Nanjing University of Science and Technology
Submit Comment
Verify Code Change Another
All Comments
Important Date
  • Conference Date

    Nov 02

    2020

    to

    Nov 04

    2020

  • Oct 27 2020

    Draft paper submission deadline

  • Nov 03 2020

    Contribution Submission Deadline

  • Nov 04 2020

    Registration deadline

  • Nov 17 2020

    Final Paper Deadline

Sponsored By
IEEE IAS Student Chapter of Huazhong University of Science and Technology (HUST)
Organized By
Huazhong University of Science and Technology
Contact Information