A Lossless and Passive Voltage Spikes Clamping Circuit for SiC HERIC Inverter
ID:61
View Protection:PUBLIC
Updated Time:2021-07-21 20:02:27 Hits:1359
Poster Presentation
Abstract
When HERIC(High Efficient and Reliable Inverter Concept) inverter operates at the non-unit power factor, there are larger turn-off voltage spikes on freewheeling switches than operating at the unit power factor, which increases switching loss, devices voltage stress, and electromagnetic interference. Moreover, the turn-off voltage spikes are much larger in some high-frequency applications, owing to the larger di/dt. This paper analyzes the turn-off voltage spikes of freewheeling switches when the HERIC inverter operates at the non-unit power factor. On this basis, a passive clamping circuit is proposed, which is simple, cheap, and lossless, and its principle is analyzed. Finally, a 10kW prototype was used to verify the proposed circuit.
Keywords
HERIC(High Efficient and Reliable Inverter Concept),Passive and lossless clamp absorption circuit,Non-unity power factor,Photovoltaic-energy storage system
Submission Author
Yong Li
Huazhong University of Science and Technology
Shanxu Duan
Huazhong University of Science and Technology
Qiqi Li
Huazhong University of Science and Technology
Submit Comment