Control strategy of three-phase T-type three-level converter with reactive power compensation function
ID:277 View Protection:ATTENDEE Updated Time:2022-05-19 15:03:53 Hits:336 Poster Presentation

Start Time:Pending(Asia/Shanghai)

Duration:Pending

Session:No Session »

Video No Permission Presentation File

Tips: Only the registered participant can access the file. Please sign in first.

Abstract
Through the analysis of the three-phase T-type three-level converter and the feedforward decoupling control strategy, a mathematical model in the d-q coordinate system is established. In order to realize the independent control of active and reactive power, a double closed-loop control strategy of current inner loop and voltage outer loop is designed, and the reactive power compensation function is realized on the basis of changing the reactive power component. Finally, the correctness and rationality of the current loop and voltage loop controller parameter design are verified through PLECS simulation.
Keywords
three-phase T-type; three-level; reactive power; a double closed-loop