Lightning Protection for the Transmission Line of ± 800kV UHVDC Single Circuit and 500kV EHVAC Double Circuit Erected on the Same Tower
ID:303 View Protection:ATTENDEE Updated Time:2022-05-20 08:58:24 Hits:283 Poster Presentation

Start Time:Pending(Asia/Shanghai)

Duration:Pending

Session:No Session »

Video No Permission Presentation File Attachment File

Tips: Only the registered participant can access the file. Please sign in first.

Abstract
For some ± 800kV UHVDC projects, due to the limitation of corridor, some transmission lines need ± 800kV UHVDC and 500kV EHV AC circuit to be erected on the same tower. When ±800kV transmission line and 500kV line are erected on the same tower, the height of the tower is further increased, and the lightning area is increased, so it is important to research the lightning protection and adopt proper lighting protection strengthening measures. In this paper, the lightning protection scheme is determined by the standard named as “Guide for lightning protection of overhead transmission lines”. Based on the transmission line of ± 800kV UHVDC single circuit and 500kV EHVAC double circuit erected on the same tower from Baihetan to Zhejiang, the preliminary results were given. To meet the control value of flashover rate, two lightning protection strengthening measures were proposed, and the results have been used in the design of the transmission line from Baihetan to Zhejiang.
Keywords
±800KV, lightning protection, ±800kV UHVDC and 500kV EHVAC erected on the same tower, shielding failure flashover rate, back flashover rate
Speaker
ZhangLiuchun
ProfessionalEngineer China Electric Power Research Institute

Liuchun Zhang, Phd, a professor who works at the Department of High Voltage, China Electric Power Research Institute. She is a Chartered Engineer (CEng) and a Registered Equipment Supervisor. She has worked in the fields of lightning and overvoltage protection of power system, insulation coordination and gas discharge for over 15 years. She has rich research experiences of lightning protection design and insulation coordination for UHVDC and UHVAC transmission and transformation engineering.
She led the research on lightning protection design and insulation coordination for the first ±1100kV UHVDC transmission project in the world. She has led and accomplished more than 50 projects on the lightning protection design and insulation coordination for the engineering with the voltage level of ±1100kV, ±800kV, 1000kV, 750kV and 330kV. She has authored or co-authored more than 40 publications, and jointly won over 20 Scientific and Technological Awards in the related area.

Submit Comment
Verify Code Change Another
All Comments
Important Date
  • Conference Date

    May 27

    2022

    to

    May 29

    2022

  • Feb 28 2022

    Draft paper submission deadline

  • May 29 2022

    Registration deadline

  • Jun 22 2022

    Contribution Submission Deadline

Sponsored By
IEEE Beijing Section
China Electrotechnical Society
Southeast University
Supported By
IEEE Industry Applications Society
IEEE Nanjing Section
Contact Information