Characteristics of Alternating Current Induced Discharges with Live Working Robot
ID:524 View Protection:ATTENDEE Updated Time:2022-05-21 18:57:53 Hits:366 Poster Presentation

Start Time:Pending(Asia/Shanghai)

Duration:Pending

Session:No Session »

Presentation File

Tips: Only the registered participant can access the file. Please sign in first.

Abstract
When a live working robot enters/leaves a highvoltage conductor, the induced discharge will cause violent electromagnetic field changes, which may cause the robot to refuse to move, misuse or even damage. In order to clarify the AC induction discharge characteristics of live working robots, an AC induction discharge test system and a pulse current measurement system conforming to the IEC 61000-4-2 standard are established. The induction discharge test of the robot is carried out in an anechoic chamber. The robot's arcing current was measured using a broadband pulse current sensor and a floating oscilloscope. The measurement results show that the rise time of a single current pulse is 0.2-10ns, the duration is about 800ns, the frequency is within 1.3GHz, and the main energy is concentrated within 100MHz. As the gap between the robot and the conductor decreases, the number of induced discharge current pulses increases, the pulse amplitude increases first, and then decreases when it reaches a certain value. As the voltage increases, the AC induced discharge current of the robot also increases. The magnitude of the robot's AC induced discharge current is related to the robot's capacitance to ground. The larger the capacitance to ground, the larger the discharge current. Through the statistical analysis of 2000 sets of measurement data, the regression formulas of the induced discharge current and voltage, capacitance and the gap between the robot and the wire are obtained. The results show that the AC induced discharge of the robot is different from the electrostatic discharge. According to the test results and the current regression formula, the electromagnetic interference protection design of the robot and the electromagnetic compatibility standard of the robot can be formulated. 
Keywords
Induced discharges;Discharge current;Live working robot;Current Pulse;Electromagnetic disturbance
Speaker
LIUXingfa
high voltage & EMC 中国电力科学研究院有限公司

I was Born in 1979, professor level senior engineer, graduated from Huazhong University of science and technology, and worked in Electric Power Research Institute in 2007. I have been engaged in the research of electromagnetic compatibility and electromagnetic environment of power system.

Submit Comment
Verify Code Change Another
All Comments
Important Date
  • Conference Date

    May 27

    2022

    to

    May 29

    2022

  • Feb 28 2022

    Draft paper submission deadline

  • May 29 2022

    Registration deadline

  • Jun 22 2022

    Contribution Submission Deadline

Sponsored By
IEEE Beijing Section
China Electrotechnical Society
Southeast University
Supported By
IEEE Industry Applications Society
IEEE Nanjing Section
Contact Information