282 / 2022-09-29 22:54:17
Case studies of cathodic prevention and cathodic protection for reinforced concrete structures and steel-framed masonry structures
reinforced concrete structures, steel-framed masonry structures, corrosion, cathodic protection, cathodic prevention.
Abstract Accepted
Yu-You WU / Foshan University
Corrosion of steel is one of the major factors affecting the durability of reinforced concrete infrastructure and steel-framed masonry structures such as bridges, buildings, parking structures, harbors and jetties, cooling towers due to the carbonation of concrete or mortar, ingress of chlorides from either marine environments or deicing salts, resulting in the serious loss of steel section,  the cracking, delamination, and spalling of concrete or masonry.

Cathodic prevention (CPre) is widely employed on newly constructed structures while cathodic protection (CPro) is generally used on existing structures, both are exposed to aggressive environments. This presentation reports an update on the application of CPre and CPro systems on bridges, buildings, nuclear cooling towers, jetties, etc. In the meantime, the design, installation, and performance monitoring of these systems are also included.

 
Important Date
  • Conference Date

    Mar 11

    2023

    to

    Mar 13

    2023

  • Feb 17 2023

    Draft paper submission deadline

  • Feb 17 2023

    Early Bird Registration

  • Mar 13 2023

    Registration deadline

Sponsored By
Shenzhen University
The Hong Kong Polytechnic University