60 / 2022-06-28 14:14:05
Modeling of Electric Arc Furnace for Power Quality Analysis
electric arc furnace; harmonics; voltage flicker; power quality
Final Paper
Ruiyang Xu / Huazhong University of Science and Technology
Shaoxiang Ma / Huazhong University of Science and Technology
Ming Zhang / Huazhong University of Science and Technology
Electric arc furnace (EAF) is one of the typical nonlinear loads in distribution network, which causes power quality problems such as harmonics and voltage flicker. In this paper, a time-domain simulation of AC EAF model for the study of power quality is established in MATLAB/Simulink and a simple multi-step parameter estimation method is proposed for a given EAF load. Considering the specific structure of EAF transformer, the arc model is obtained by combination and modification of classical Cassie and Mayr equations. The arc model is dynamically modulated by superimposing the sinusoidal and band-limited white noise signal to simulate the actual working conditions. The comparison between the simulated results and the measured data shows that the model is able to describe the time-varying, nonlinear and unbalanced characteristics of EAF accurately, which provides a reference for the research of the low-voltage side of the EAF transformer power quality problems.

 