The Saturated Inductance of the Magnetic Switch in RSD-based Pulse Circuit
ID:82 View Protection:ATTENDEE Updated Time:2025-10-11 22:48:20 Hits:205 Poster Presentation

Start Time:2025-11-09 09:03(Asia/Shanghai)

Duration:1min

Session:P Poster presentation » P22.Power electronics technology and application

No files

Abstract
Reversely switched dynistor (RSD) is a semiconductor switch which is suitable to be used in pulsed power systems. In many trigger circuits of RSD, a magnetic switch is usually needed. In this study, the saturated inductance of the magnetic switch is simulated. In addition, the relative permeability of the magnetic switch in the forward saturation process is measured. Based on the experimental results, if H is in the range of 1000 A/m to 2000 A/m, the relative permeability should be set between 4 and 5.5. If H is in the range of 2000 A/m to 5000 A/m, the relative permeability should be set between 3 and 4.5. However, at the H of tens of kA/m, the inductance of the magnetic switch can be calculated at relative permeability is 1.
Keywords
RSD,magnetic switch,saturated inductance
Speaker
Zhiwei Kang
Master degree candid Huazhong University of Science and Technology

Submission Author
Zhiwei Kang Huazhong University of Science and Technology
Lv Yiliang Huazhong University of Science and Technology
Submit Comment
Verify Code Change Another
All Comments
Important Date
  • Conference Date

    Nov 07

    2025

    to

    Nov 09

    2025

  • Oct 30 2025

    Draft paper submission deadline

  • Nov 10 2025

    Registration deadline

Sponsored By
IEEE西南交通大学IAS学生分会
Organized By
西南交通大学电气工程学院
SPACI车网关系研究室
四川大学电力系统稳定与高压直流输电研究团队